The complete remote control unit for your
|
The remote control unit
With the
Principle of the remote control
History
Device configuration
Sample applications
Automatic functions
Notifications of emergency
Measured value recording
Further features
Advantages over a PC as host
Security
Further development projects for the future
Available accessories
Technical data
Physical dimensions
Further information request
Term assertion
Document at the beginning of
Further on-line information
Back to the start page
the house fuse box installs |
| 6 | digital outputs
(5 over relay contacts floating
decouples, 1 semiconductor switch) |
| 2 | similar outputs (for placing functions) |
| 6 | digital inputs |
| 6 | similar inputs (with integrated A/D transducer) |
| 1 | bi-directional INTERFACE for further components |
We would like to thank you here the numerous aids for their
valuable tips and notes, without which this development would not have
been possible.
The developers
|
|
|
|
|
| Temperature sensor: | LM 34 for interior and exterior mounting |
| LM 34 as dipping feelers for liquids | |
| PT 100 for precision measurements | |
| further accessories on request |
| Supply voltage | 230V ±10% (external power pack) |
| Capacity | 10W |
| Temperature range | 0-45°C |
| Environment dampness | 20%-80% r.F. |
| Microcontroller | MC68HC11A1FN |
| Clock frequency | 8 MHz |
| Contact rating per contact | 1 KW |
| Type of housing | RCP 2000 automatic controller wall housings with hinged transparent cover, locking catch |
| Enclosure | IP 65 |
| Dimensions | (L x B x H) 219 x 185 x 104.5 mm |
| Weight | 1500 g |
All pictures made with Connectix ColorQuickCam |
|
| A/D transducer | Function group one similar physical dimension into a digital (computerized) size converts. |
| Output, similarly | Pair of output terminals with that a similar voltage within the area: 0-5/0-10 V one outputs. |
| Output, digitally | Pair of output terminals with only two statuses (in/out or 0/5 V) to be output know. |
| Client | The local PC by that the remote control instructions to be sent |
| CMOS | Name for integrated circuits, which are manufactured in Complementary Metall Oxid Silizium technique. Special advantages: small energy dissipation, high fail-safe characteristic |
| Input, similarly | Pair of input clamps with that a similar voltage within the area: 0-5/0-10 V one creates. Serves for measuring physical dimension. |
| Input, digitally | Pair of input clamps with only two statuses (in/out or 0/5 V) are relevant. |
| EPROM | Name for Erasable and Programmable Read Only Memory. An electronic memory module, as the program is contained, and which in case of failure of the mains voltage its data maintains. |
| GSM | Sign of Global System for Mobilkommunikation. The mostly network carriers offer in the meantime the service to pass received text messages on your mobile telephone which are then represented on the display. |
| Host | Remote PC or RCS-1- mechanism those becomes remote controlled |
| INTERFACE, bidirectional | Internal link port, which can transmit and receive data. This interface serves the purpose of the future system expansion (e.g. positioning, camera module, I/O-Expander etc.) |
| LM 34 | A temperature sensor with a temperature spectrum of It is characterised by high accuracy and outstanding linearity. |
| IP 65 | Standardized class specification against the penetration of foreign substances. Enclosure IP 65: Protection against penetration of dust and jet water. |
| Only reading status | Device mode, with the user a possibility does not have to change the adjustments, but only completely determined information to recall can |
| PT 100 | For special applications the PT 100 is available. A precision temperature sensor in platinum nickel technique. |
| Quiescent current loop | Circuit principle with that several monitoring contacts are switched into series and by a current to be flowed through. If one or more contacts are opened, a switching operation (alarm) is released. |
| Pager | Electronic and battery-operated text call receiver for the vest pocket. It enables the mobile receipt of messages in the entire federal territory over radio signals. |
| Relay contact, floating | Relay output of which is electrically isolated from remaining electronics. Enabled so switching an external voltage, e.g. mains voltage 230 V. |
| Time switch function | Enables a time-of-day-dependent and automatic execution of switching functions, without a previous a selection of the user is necessary. |
| Placing function | Applications, with which devices must be brought in a certain position or position. Beispiel: Ventilpositionierung (übliche Stellgröße: 0..10 Volt) |
| Placing function | Applications, with which DEVICES must brought in a certain position or position.
Example: Valve positioning (usual correcting variable: 0...10 V) |
| System, self-starting | There the RCS-1- computer system is equipped with a fixed value program memory, starts it the program run after switching on of the operating voltage on completely automatically and without operator control. |
| Linkage, logical | Firmly defined statuses at several inputs, which must be available, in order to release a switching operation. |
| Watch Dog System | An additional system of which constantly the function correct of the microprocessor monitors, and in the case of disturbance the main system lets a restart of the program execute automatically. |
| Counter operation | All input status changes at the digital inputs are counted and stored. Max. counting rate is 16 cycles per second. |
| Two-step action controller | Regulation-technical term, with which two data points are defined. The measured value exceeds the upper data point an attached unit is switched off, or when falling below the lower data point switched on accordingly. The intermediate area (hysteresis) can be selected freely. |